working principle:

The anorectal therapy instrument uses the principle of radiofrequency thermal dry core internal heat, which is designed based on the electrolysis constant and electrical conductivity of the human hemorrhoid tissue under the action of a discontinuous capacitive electric field. The tissue fluid dries within a time, the blood vessel is closed, the cutting site is not carbonized, does not bleed, and does not harm the surrounding tissues. After a few days, the hemorrhoid nucleus sheds itself.

The anorectal therapy instrument contains the functions of electric forceps, electric forceps, electric resection, and electrocoagulation. The hemorrhoid can be clamped. After the electric clamp operation is performed, the instrument automatically alarms and stops working. The electrosurgical function can complete normal tissue incision and tissue resection. Electrocoagulation can coagulate the incised tissue. Electric tweezers can make local bleeding vessels adhere and occlude, achieving the purpose of one machine for multiple purposes.

 

Main technical parameters and characteristics:

 

频率 47--63 Hz 1. Power supply range: AC voltage 170--260V frequency 47--63 Hz

2. Output power: 0-99 W is adjustable during cutting and coagulation. The minimum step unit is 1W.

              Electric pliers and electric tweezers are adjustable from 15 to 50 W, and the smallest stepping unit is 1 W.

3. Working frequency: 380KHz ± 10% when cutting, pliers and electric tweezers; 250KHz ± 10% when setting.

4. When the electric forceps and electric tweezers work, when the diseased part dries up, the output is automatically turned off and the alarm is given.

电钳表面带有铜保护层,可使被钳夹组织干结,不出现碳化; 5. The surface of the electric clamp is provided with a copper protective layer, which can make the clamped tissue dry and not carbonize;

6, the neutral electrode is not connected with automatic protection and alarm.

 

Standard equipment configuration:

Host: 1 set;

Healing pens: 1

Electrode plate: 2;

Treatment head: 1 set (knife treatment head, needle treatment head, spherical treatment head, curved treatment head);

Electric pliers: 2

Electric tweezers: 1

Electric clamp line: 1;

Foot switch: 1;

Ground wire: 1;

Power cord: 1 pc.